3 KiB
scope-tui
A simple oscilloscope/vectorscope in your terminal
Currently only for Linux (with Pulseaudio)
Why
I really love cava. It provides a crude but pleasant frequency plot for your music: just the bare minimum to see leads solos and basslines.
I wanted to also be able to see waveforms, but to my knowledge nothing is available. There is some soundcard oscilloscope software available, but the graphical GUI is usually dated and breaks the magic.
I thus decided to solve this very critical issue with my own hands! And over a night of tinkering with pulseaudio (via libpulse-simple-binding) and some TUI graphics (via tui-rs),
the first version of scope-tui
was developed, with very minimal settings given from command line, but a bonus vectorscope mode baked in.
Usage
$ scope-tui [OPTIONS] [DEVICE]
Arguments:
[DEVICE] Audio device to attach to
Options:
-b, --buffer <BUFFER> Size of audio buffer, and width of scope [default: 8192]
-r, --range <RANGE> Max value, positive and negative, on amplitude scale [default: 20000]
--scatter Use vintage looking scatter mode instead of line mode
--vectorscope Combine left and right channels into vectorscope view
--tune <TUNE> Tune buffer size to be in tune with given note (overrides buffer option)
--sample-rate <SAMPLE_RATE> Sample rate to use [default: 44100]
--server-buffer <SERVER_BUFFER> Pulseaudio server buffer size, in block number [default: 32]
--no-reference Don't draw reference line
--no-braille Don't use braille dots for drawing lines
-h, --help Print help information
-V, --version Print version information
The audio buffer size directly impacts resource usage, latency and refresh rate and its limits are given by the audio refresh rate. Larger buffers are slower but less resource intensive. A good starting value might be 8192
To change audio buffer size, the PulseAudio client must be restarted. Because of this, such option is configurable only at startup.
Controls
- Use
q
orCTRL+C
to exit - Use
<SPACE>
to pause and resume display - Use
-
and=
to decrease or increase range (_
and+
for smaller steps) - Use
v
to toggle vectorscope mode - Use
s
to toggle scatter mode - Use
h
to toggle interface - Decrease/increase terminal font size to increase/decrease scope resolution.
About precision
While "scatter" mode is as precise as Pulseaudio and the terminal lets us be, "line" mode simply draws a straight line across points, meaning high frequencies don't get properly represented.
Latency is kept to a minimum thanks to small buffer and block sizes.
Sample rate can be freely specified but will ultimately be limited by source's actual sample rate.